HD - manifold
1 - 10-Fold
To connect one or more individual gas cylinders to a cylinder battery.
Every individual connection is equipped with a non-return valve, which prevents a return flow or running dry. A main shut-off valve allows separation of the entire side from the supply and the manifold can be depressurised via a bleed valve.
All components are high-pressure resistant (BAM tested) and thus withstand the operating pressure of 20,000 kPa (200 bar). Two cylinders in each case are connected as single or double versions via a distribution bend to the manifold.
Design
- High pressure manifold 1 to 10-fold
- Individual valves per connection
- Main shut-off valve for the entire manifold
- Bleed valve with solder connection
HD - distribution bend
For the high pressure connection between the cylinder valve and manifold. Version with compensating spiral, as manual connection or hexagonal nut, in a single or double version.
HD - connecting pipe
To connect the manifold with the switchover system.
- HD - manifold
Technical data
Inlet pressure max: 20.000 kPa (200 bar) Operating temperature: +10° bis +40° C Separation between cylinders: 300 mm Anbauschnellkupplung
HD - manifold, 1-fold, complete 327.301 HD - manifold, 2-fold, complete 900.522 HD - manifold, 3-fold, complete 900.523 HD - manifold, 4-fold, complete 900.524 HD - manifold, 5-fold, complete 900.525 HD - manifold, 6-fold, complete 900.526 HD - manifold, 7-fold, complete 900.527 HD - manifold, 8-fold, complete 900.528 HD - manifold, 9-fold, complete 900.529 HD - manifold, 10-fold, complete 900.530 - HD - distribution bend
Usage
For the high pressure connection between the cylinder valve and manifold. Version with compensating spiral, as manual connection or hexagonal nut, in a single or double version.Technical data
Operating pressure max.: 20.000 kPa (200 bar) Inlet: gas-specific Outlet: gas-specific HD - distribution bend
HD - distribution bend, manual connection, O2, single 325.414 HD - distribution bend, manual connection, O2, double 324.414 HD - distribution bend, manual connection, AIR, single 325.524 HD - distribution bend, manual connection, AIR, double 324.514 HD - distribution bend, manual connection, N2O, single 325.415 HD - distribution bend, manual connection, CO2, single 325.426 Other gases, connections and norms on request - HD - connecting pipe
Usage
To connect the manifold with the switchover system.Technical data
Operating pressure max.: 20.000 kPa (200 bar) Inlet: G ¾" Outlet: G ¾" HD - connecting pipe
HD - connecting pipe for 2x manifold 327.304 HD - connecting pipe, manifold with MC 2025 E / P 324.010 HD - connecting pipe, manifold with MC 2100 / 2050 E / P 324.001 HD - connecting pipe, manifold 1-fold with MC 2025 E / P 324.015 HD - connecting pipe, manifold with reserve panel 324.013 HD - connecting pipe, manifold 1-fold with HU 10 325.732 HD - connecting pipe, manifold with HU 10 325.733 HD - connecting pipe, manifold 1-fold with reserve panel 324.018